Please use this identifier to cite or link to this item: https://hdl.handle.net/2440/71788
Citations
Scopus Web of Science® Altmetric
?
?
Type: Journal article
Title: Interobserver and intraobserver variability in pH-impedance analysis between 10 experts and automated analysis
Author: Loots, C.
van Wijk, M.
Blondeau, K.
Dalby, K.
Peeters, L.
Rosen, R.
Salvatore, S.
Wenzl, T.
Vandenplas, Y.
Benninga, M.
Omari, T.
Citation: Journal of Pediatrics, 2011; 160(3):441-446
Publisher: Mosby Inc
Issue Date: 2011
ISSN: 0022-3476
1097-6833
Statement of
Responsibility: 
Clara M. Loots, Michiel P. van Wijk, Kathleen Blondeau, Kasper Dalby, Laura Peeters, Rachel Rosen, Silvia Salvatore, Tobias G. Wenzl, Yvan Vandenplas, Marc A. Benninga, and Taher I. Omari
Abstract: <h4>Objective</h4>To determine interobserver and intraobserver variability in pH-impedance interpretation between experts and accuracy of automated analysis (AA).<h4>Study design</h4>Ten pediatric 24-hour pH-impedance tracings were analyzed by 10 observers from 7 world groups and with AA. Detection of gastroesophageal reflux (GER) episodes was compared between observers and AA. Intraobserver agreement was assessed in 3 observers after 3 to 5 months.<h4>Results</h4>Overall, 1242 liquid and mixed GER events were detected, 490 (42%) were scored by the majority of observers, yielding moderate agreement (Cohen's kappa [κ] = 0.46). Intraclass co-efficient for numbers of GER per study was 0.84 (P < .001). AA has 94% sensitivity rate and 74% specificity rate compared with majority consensus (≥6 observers). Agreement for gas GER was poor (κ = 0.11). Intraobserver agreement was κ = 0.49, κ = 0.71, and κ = 0.85 in 3 observers.<h4>Conclusion</h4>Interobserver agreement in combined pH-multichannel intraluminal impedance analysis in experts is moderate; only 42% of GER episodes were detected by the majority of observers. Detection of total GER numbers is more consistent. Considering these poor outcomes, AA seems favorable compared with manual analysis because of its reproducibility. However, the lower specificity rate suggests the need for refinement of AA before widespread use can be advocated.
Keywords: AA, Automated analysis
GER, Gastroesophageal reflux
κ, Cohen’s kappa
MMS, Medical Measurement Systems (Enschede, The Netherlands)
MII, Multichannel intraluminal impedance
pH-MII, Combined pH-multichannel intraluminal impedance
Rights: Copyright © 2012 Mosby Inc.
DOI: 10.1016/j.jpeds.2011.08.017
Published version: http://dx.doi.org/10.1016/j.jpeds.2011.08.017
Appears in Collections:Aurora harvest
Paediatrics publications

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.