Please use this identifier to cite or link to this item: https://hdl.handle.net/2440/137276
Citations
Scopus Web of Science® Altmetric
?
?
Type: Journal article
Title: MiOXSYS® andOxiSperm® II assays appear to provide no clinical utility for determining oxidative stress in human sperm—results from repeated semen collections
Other Titles: MiOXSYS and OxiSperm II assays appear to provide no clinical utility for determining oxidative stress in human sperm—results from repeated semen collections
Author: Castleton, P.
Gyawali, P.
Mathews, N.
Mutuku, S.M.
Sharkey, D.J.
McPherson, N.O.
Citation: Andrology, 2023; 11(8):1566-1578
Publisher: Wiley
Issue Date: 2023
ISSN: 2047-2919
2047-2927
Statement of
Responsibility: 
Patience Castleton, Prabin Gyawali, Nicola Mathews, Shadrack Mulinge Mutuku, David James Sharkey, Nicole Olivia McPherson
Abstract: Background: Oxidative stress in semen contributes up to 80% of all infertility diagnosis. Diagnostics to measure oxidative stress in semen was recently added to the 6th edition WHO methods manual, although diagnostic predictive values need to be interpreted with caution as there are still several research questions yet to be answered. Objectives: To determine the natural fluctuations in semen redox indicators (MiOXSYS® and OxiSperm® II) within and between men and their association with markers of sperm oxidative stress. Materials and methods: Total, 118 repeat semen samples from 31 generally healthy men aged 18–45 years, over 6 months. Standard semen analysis as per 5th WHO manual. Semen redox levels measured via MiOXSYS® and OxiSperm® II. Additional attributes of sperm quality; HBA® binding assay and sperm hyperactivation and oxidative stress; DNA fragmentation (Halo® Sperm) and lipid peroxidation (BODIPY™ 581/591 C11) were assessed. Results: Samples with high redox-potential (MiOXSYS® ≥1.47 sORP/10⁶ sperm/ml) had lower sperm, motility, morphology and higher DNA fragmentation (P<0.05). Upon further analysis, these associations were driven solely by the adjustment of sperm concentration (10⁶/ml) in normalised redox-potential.No significant associations between NBT-reactivity (OxiSperm® II) and measures of the sperm function or oxidative stress were observed (P > 0.05). Fluctuations in semen redox levels varied greater between men than within men over the study period. Discussion: Neither MiOXSYS® nor OxiSperm® II assays were predictive of sperm function or sperm oxidative stress. This was likely due at least in part to limited understanding of their biochemistry and clinical application. As a result, these assays seem to provide no additional clinical utility beyond that of a standard semen analysis, highlighting the imperative for the development of new robust point-of-care devices for accurately determining sperm oxidative stress. Conclusion: These findings suggest that MiOXSYS® and OxiSperm® II systems for the measurement of sperm oxidative stressmay have limited diagnostic potential.
Keywords: fertility; infertility; ROS; seminal plasma; spermatazoa
Description: First published: 01 December 2022
Rights: ©2022 The Authors. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
DOI: 10.1111/andr.13356
Grant ID: http://purl.org/au-research/grants/arc/DE220101449
Published version: http://dx.doi.org/10.1111/andr.13356
Appears in Collections:Obstetrics and Gynaecology publications

Files in This Item:
File Description SizeFormat 
hdl_137276.pdfPublished version1.67 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.