Please use this identifier to cite or link to this item: https://hdl.handle.net/2440/93140
Citations
Scopus Web of Science® Altmetric
?
?
Type: Journal article
Title: International comparative evaluation of knee replacement with fixed or mobile non-posterior-stabilized implants
Author: Namba, R.
Graves, S.
Robertsson, O.
Furnes, O.
Stea, S.
Puig-Verdié, L.
Hoeffel, D.
Cafri, G.
Paxton, E.
Sedrakyan, A.
Citation: Journal of Bone and Joint Surgery: American Volume, 2014; 96(Suppl. 1(E)):52-58
Publisher: Journal of Bone and Joint Surgery Inc.
Issue Date: 2014
ISSN: 0021-9355
1535-1386
Statement of
Responsibility: 
Robert Namba, Stephen Graves, Otto Robertsson, Ove Furnes, Susanna Stea, Lluis Puig-Verdie, Daniel Hoeffel, Guy Cafri, Elizabeth Paxton
Abstract: Background: Mobile-bearing total knee prostheses were designed to reduce wear and improve implant survivorship following total knee arthroplasty. However, the benefit of mobile-bearing total knee arthroplasty remains unproven. Both mobile-bearing and fixed-bearing total knee arthroplasty implants are available in posterior-stabilized and non-posterior-stabilized designs. With the latter, the implant does not recreate the function of the posterior cruciate ligament (PCL) with a posterior-stabilizing cam mechanism. The purpose of the present study was to compare mobile-bearing, non-posterior-stabilized devices with fixed-bearing, non-posterior-stabilized devices used in total knee arthroplasty through a novel multinational study design. Methods: Through the use of a distributed health data network, primary total knee arthroplasties performed for osteo-arthritis from 2001 to 2010 were identified from six national and regional total joint arthroplasty registries. Multivariate meta-analysis was performed with use of linear mixed models, with the primary outcome of interest being revision for any reason. Survival probabilities and their standard errors were extracted from each registry for each unique combination of the covariates. Results: A total of 319,616 patients (60% female) underwent non-posterior-stabilized total knee arthroplasty. A fixed-bearing, non-posterior-stabilized design was used in 258,190 (81%) of the knees and a mobile-bearing, non-posterior-stabilized design in 61,426 (19%) of the knees. Sixty-nine percent of the patients who received a fixed-bearing implant were over sixty-five years of age, compared with 63% of those who received a mobile-bearing implant. Mobile-bearing designs had a higher risk of revision, with a hazard ratio of 1.43 (95% confidence interval, 1.36 to 1.51; p<0.001).Conclusions: Previous comparisons of mobile-bearing and fixed-bearing total knee arthroplasty outcomes have been inconclusive. The current study utilized an advanced, harmonized distributed analysis of six national and regional joint-replacement registries. To our knowledge, it is the largest analysis of mobile-bearing total knee arthroplasty to date. Mobile-bearing, non-posterior-stabilized designs presented a greater risk of failure than was found for fixed-bearing,nonposterior stabilized designs.Caution should be used in the selection of the mobile-bearing non-posterior-stabilized design for total knee replacement.
Keywords: Knee Joint
Humans
Osteoarthritis, Knee
Range of Motion, Articular
Arthroplasty, Replacement, Knee
Registries
Prosthesis Design
Knee Prosthesis
Adult
Aged
Aged, 80 and over
Middle Aged
Female
Male
Rights: © 2014 by the Journal of Bone and Joint Surgery, Incorporated
DOI: 10.2106/JBJS.N.00466
Published version: http://dx.doi.org/10.2106/jbjs.n.00466
Appears in Collections:Aurora harvest 7
Orthopaedics and Trauma publications

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.