Please use this identifier to cite or link to this item:
https://hdl.handle.net/2440/88880
Citations | ||
Scopus | Web of Science® | Altmetric |
---|---|---|
?
|
?
|
Type: | Journal article |
Title: | Long-term clinical outcomes with the next-generation Resolute Stent System: a report of the two-year follow-up from the RESOLUTE clinical trial |
Author: | Meredith, I. Worthley, S. Whitbourn, R. Walters, D. McClean, D. Ormiston, J. Horrigan, M. Wilkins, G. Hendriks, R. Matsis, P. Muller, D. Cutlip, D. |
Citation: | EuroIntervention, 2010; 5(6):692-697 |
Publisher: | Baishideng |
Issue Date: | 2010 |
ISSN: | 1969-6213 1774-024X |
Statement of Responsibility: | Antonina A Mikocka-Walus |
Abstract: | AIMS: The 12-month results of RESOLUTE were favourable for the new Resolute stent. Two-year safety and efficacy results from RESOLUTE have been evaluated and are now reported. METHODS AND RESULTS: RESOLUTE was a prospective, multicentre, non-randomised, single-arm, controlled trial of the Resolute stent in 139 participants with symptomatic ischaemic heart disease due to single de novo lesions in a native coronary artery. The 2-year rates of MACE (all-cause death, myocardial infarction, emergent cardiac bypass surgery, and target lesion revascularisation [TLR]), death, late stent thrombosis, target vessel revascularisation (TVR), and target vessel failure (TVF) were assessed. Clinical events included two MACE (one TLR; one non-cardiac death) occurring between year one and two resulting in cumulative 2-year TLR, TVR, and TVF rates of 1.4%, 1.4%, and 7.9%, respectively. One possible stent thrombosis event occurred in the first year after stent implantation however no late or very late ARC-defined definite and probable stent thromboses occurred through two years. CONCLUSIONS: The 2-year data from RESOLUTE demonstrated no safety concerns including no late stent thrombosis or loss of effectiveness with the Resolute stent. The finding that few events occurred in year two is encouraging, yet requires verification in a larger population. |
Keywords: | Humans Coronary Stenosis Myocardial Infarction Coronary Angiography Treatment Outcome Incidence Survival Rate Coated Materials, Biocompatible Prospective Studies Prosthesis Design Myocardial Revascularization Stents Drug-Eluting Stents Middle Aged Time Factors Australia New Zealand Female Follow-Up Studies Male Graft Occlusion, Vascular |
Rights: | © 2010 Baishideng. All rights reserved. |
DOI: | 10.4244/EIJV5I6A114 |
Published version: | http://dx.doi.org/10.4244/eijv5i6a114 |
Appears in Collections: | Aurora harvest 2 Medicine publications |
Files in This Item:
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.