Please use this identifier to cite or link to this item:
https://hdl.handle.net/2440/58399
Citations | ||
Scopus | Web of Science® | Altmetric |
---|---|---|
?
|
?
|
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Wong, K. | - |
dc.contributor.author | Kelso, R. | - |
dc.contributor.author | Worthley, S. | - |
dc.contributor.author | Sanders, P. | - |
dc.contributor.author | Mazumdar, J. | - |
dc.contributor.author | Abbott, D. | - |
dc.contributor.editor | Lim, C. | - |
dc.contributor.editor | Goh, J. | - |
dc.date.issued | 2009 | - |
dc.identifier.citation | 13th International Conference on Biomedical Engineering ICBME 2008 Singapore 3–6 December 2008 / Chwee Teck Lim and James C.H. Goh (eds.): pp.569-573 | - |
dc.identifier.isbn | 9783540928409 | - |
dc.identifier.issn | 1680-0737 | - |
dc.identifier.issn | 1433-9277 | - |
dc.identifier.uri | http://hdl.handle.net/2440/58399 | - |
dc.description.abstract | This paper presents flow results of a magnetic resonance imaging velocimetry system which relies on fluid motion estimation, and uses vorticity map differencing for calibrating its reliability. To validate this new concept, phase contrast magnetic resonance imaging on the right atrium of a healthy subject has been suggested. The study has demonstrated the state of change in blood flow patterns within a cardiac chamber using our implemented system and a well established flow imaging modality. Based on the gold standard imaging technique, flow fields can be used to establish a set of reference data to compare against magnetic resonance fluid motion tracking results. We conclude that our validated technique can be reliable enough for establishing a cardiac based velocimetry system. | - |
dc.description.statementofresponsibility | K.K.L. Wong, R.M. Kelso, S.G. Worthley, P. Sanders, J. Mazumdar and D. Abbott | - |
dc.language.iso | en | - |
dc.publisher | Springer | - |
dc.relation.ispartofseries | IFMBE Proceedings ; 23 | - |
dc.rights | © Springer | - |
dc.source.uri | http://dx.doi.org/10.1007/978-3-540-92841-6_140 | - |
dc.subject | Phase contrast magnetic resonance imaging | - |
dc.subject | Fluid motion tracking | - |
dc.subject | Right atrium | - |
dc.title | Flow imaging and validation of MR fluid motion tracking | - |
dc.type | Conference paper | - |
dc.contributor.conference | International Conference on Biomedical Engineering (13th : 2008 : Singapore) | - |
dc.identifier.doi | 10.1007/978-3-540-92841-6_140 | - |
dc.publisher.place | Germany | - |
pubs.publication-status | Published | - |
dc.identifier.orcid | Kelso, R. [0000-0002-5783-9232] | - |
dc.identifier.orcid | Sanders, P. [0000-0003-3803-8429] | - |
dc.identifier.orcid | Abbott, D. [0000-0002-0945-2674] | - |
Appears in Collections: | Aurora harvest Electrical and Electronic Engineering publications |
Files in This Item:
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.