Please use this identifier to cite or link to this item: https://hdl.handle.net/2440/51512
Citations
Scopus Web of ScienceĀ® Altmetric
?
?
Type: Journal article
Title: The effect of electrogram duration on quantification of complex fractionated atrial electrograms and dominant frequency
Author: Stiles, M.
Brooks, A.
John, B.
Shashidar, M.
Wilson, L.
Kuklik, P.
Dimitri, H.
Lau, D.
Roberts-Thomson, R.
Mackenzie, L.
Willoughby, S.
Young, G.
Sanders, P.
Citation: Journal of Cardiovascular Electrophysiology, 2008; 19(3):252-258
Publisher: Futura Publ Co
Issue Date: 2008
ISSN: 1045-3873
1540-8167
Statement of
Responsibility: 
Martin K. Stiles, Anthony G. Brooks, Bobby John, Shashidhar, Lauren Wilson, Pawel Kuklik, Hany Dimitri, Dennis H. Lau, Ross L. Roberts-Thomson, Lorraine Mackenzie, Scott Willoughby, Glenn D. Young and Prashanthen Sanders
Abstract: <h4>Introduction</h4>Sites of complex fractionated atrial electrograms (CFAEs) and highest dominant frequency (DF) have been proposed as critical regions maintaining atrial fibrillation (AF). This study aimed to determine the minimum electrogram recording duration that accurately characterizes CFAE or DF sites for ablation without unduly lengthening the procedure.<h4>Methods and results</h4>Fourteen patients with AF undergoing catheter ablation had high-density (498 +/- 174 points) biatrial mapping performed during AF before ablation. At each point, 8-second electrograms were recorded. CFAE characterization using the NavX software provided a representation of electrogram complexity (CFE-mean). CFE-mean for each point from 7-, 6-, 5-, 4-, 3-, 2-, and 1-second subsamples were compared with the index 8-second CFE-mean. Offline spectral analysis defined DF as the frequency with greatest power, and DF of subsamples were compared with index DF. Index 8-second electrogram CFE-mean was 114 +/- 20 ms for right atria and 102 +/- 17 ms for left atria (P = 0.01); DF was 5.7 +/- 0.8 Hz for right atria and 6.0 +/- 0.8 Hz for left atria (P = 0.02). Means from shorter electrograms were nonsignificantly decreased for CFE-mean and overestimated for DF (P < 0.001). Mean absolute differences between subsampled and index values ranged from 3.3 to 20.1 ms for CFE-mean and 0.11 to 1.18 Hz for DF. Subsampled electrograms deviating >10% from index values ranged from 2.5 to 56% for CFE-mean and 3.5 to 41% for DF. Intraclass correlation coefficients ranged from 0.992 to 0.788 for CFE-mean and 0.897 to 0.233 for DF. Unacceptable differences from index values were found with CFE-mean and DF from electrograms <5 seconds.<h4>Conclusion</h4>Electrograms of >or=5-second duration are required to accurately characterize CFAE and DF sites for ablation.
Keywords: Shashidhar
Humans
Atrial Fibrillation
Diagnosis, Computer-Assisted
Body Surface Potential Mapping
Sensitivity and Specificity
Reproducibility of Results
Algorithms
Time Factors
Aged
Female
Male
Description: Article first published online: 21 FEB 2008
Rights: 2008 by Futura Publishing Company, Inc
DOI: 10.1111/j.1540-8167.2007.01034.x
Published version: http://dx.doi.org/10.1111/j.1540-8167.2007.01034.x
Appears in Collections:Aurora harvest 5
Medicine publications

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.