Please use this identifier to cite or link to this item: https://hdl.handle.net/2440/42874
Citations
Scopus Web of ScienceĀ® Altmetric
?
?
Full metadata record
DC FieldValueLanguage
dc.contributor.authorMoran, J.-
dc.contributor.authorPeter, J.-
dc.contributor.authorSolomon, P.-
dc.contributor.authorGrealy, B.-
dc.contributor.authorSmith, T.-
dc.contributor.authorAshforth, W.-
dc.contributor.authorWake, M.-
dc.contributor.authorPeake, S.-
dc.contributor.authorPeisach, A.-
dc.date.issued2007-
dc.identifier.citationCritical Care Medicine, 2007; 35(1):155-164-
dc.identifier.issn0090-3493-
dc.identifier.issn1530-0293-
dc.identifier.urihttp://hdl.handle.net/2440/42874-
dc.description.abstractOBJECTIVE: Accurate measurement of temperature is vital in the intensive care setting. A prospective trial was performed to compare the accuracy of tympanic, urinary, and axillary temperatures with that of pulmonary artery (PA) core temperature measurements. DESIGN: A total of 110 patients were enrolled in a prospective observational cohort study. SETTING: Multidisciplinary intensive care unit of a university teaching hospital. PATIENTS: The cohort was (mean +/- sd) 65 +/- 16 yrs of age, Acute Physiology and Chronic Health Evaluation (APACHE) II score was 25 +/- 9, 58% of the patients were men, and 76% were mechanically ventilated. The accuracy of tympanic (averaged over both ears), axillary (averaged over both sides), and urinary temperatures was referenced (as mean difference, Delta degrees centigrade) to PA temperatures as standard in 6,703 recordings. Lin concordance correlation (pc) and Bland-Altman 95% limits of agreement (degrees centigrade) described the relationship between paired measurements. Regression analysis (linear mixed model) assessed covariate confounding with respect to temperature modes and reliability formulated as an intraclass correlation coefficient. MEASUREMENTS AND MAIN RESULTS: Concordance of PA temperatures with tympanic, urinary, and axillary was 0.77, 0.92, and 0.83, respectively. Compared with PA temperatures, Delta (limits of agreement) were 0.36 degrees C (-0.56 degrees C, 1.28 degrees C), -0.05 degrees C (-0.69 degrees C, 0.59 degrees C), and 0.30 degrees C (-0.42 degrees C, 1.01 degrees C) for tympanic, urinary, and axillary temperatures, respectively. Temperature measurement mode effect, estimated via regression analysis, was consistent with concordance and Delta (PA vs. urinary, p = .98). Patient age (p = .03), sedation score (p = .0001), and dialysis (p = .0001) had modest negative relations with temperature; quadratic relationships were identified with adrenaline and dobutamine. No interactions with particular temperature modes were identified (p > or = .12 for all comparisons) and no relationship was identified with either mean arterial pressure or APACHE II score (p > or = .64). The average temperature mode intraclass correlation coefficient for test-retest reliability was 0.72. CONCLUSION: Agreement of tympanic with pulmonary temperature was inferior to that of urinary temperature, which, on overall assessment, seemed more likely to reflect PA core temperature.-
dc.description.statementofresponsibilityMoran JL, Peter JV, Solomon PJ, Grealy B, Smith T, Ashforth W, Wake M, Peake SL, Peisach AR.-
dc.language.isoen-
dc.publisherLippincott Williams & Wilkins-
dc.source.urihttp://dx.doi.org/10.1097/01.ccm.0000250318.31453.cb-
dc.subjectAxilla-
dc.subjectArteries-
dc.subjectTympanic Membrane-
dc.subjectUrine-
dc.subjectHumans-
dc.subjectCritical Illness-
dc.subjectThermography-
dc.subjectCatheterization, Swan-Ganz-
dc.subjectMonitoring, Physiologic-
dc.subjectBody Temperature-
dc.subjectCritical Care-
dc.subjectAPACHE-
dc.subjectAnalysis of Variance-
dc.subjectLinear Models-
dc.subjectSensitivity and Specificity-
dc.subjectProspective Studies-
dc.subjectBlood Pressure-
dc.subjectAged-
dc.subjectMiddle Aged-
dc.subjectHospitals, University-
dc.subjectSouth Australia-
dc.subjectFemale-
dc.subjectMale-
dc.subjectBias-
dc.titleTympanic temperature measurements: Are they reliable in the critically ill? A clinical study of measures of agreement-
dc.typeJournal article-
dc.identifier.doi10.1097/01.CCM.0000250318.31453.CB-
pubs.publication-statusPublished-
dc.identifier.orcidMoran, J. [0000-0003-2311-0440]-
dc.identifier.orcidSolomon, P. [0000-0002-0667-6947]-
dc.identifier.orcidPeake, S. [0000-0001-6682-7973]-
Appears in Collections:Aurora harvest
Mathematical Sciences publications

Files in This Item:
There are no files associated with this item.