Please use this identifier to cite or link to this item:
https://hdl.handle.net/2440/39238
Citations | ||
Scopus | Web of Science® | Altmetric |
---|---|---|
?
|
?
|
Type: | Journal article |
Title: | Reduction of fluoroscopy exposure and procedure duration during ablation of atrial fibrillation using a novel anatomical navigation system |
Author: | Rotter, M. Takahashi, Y. Sanders, P. Haissaguerre, M. Jais, P. Hsu, L. Sacher, F. Pasquie, J. Clementy, J. Hocini, M. |
Citation: | European Heart Journal, 2005; 26(14):1415-1421 |
Publisher: | W B Saunders Co Ltd |
Issue Date: | 2005 |
ISSN: | 0195-668X 1522-9645 |
Statement of Responsibility: | Martin Rotter, Yoshihide Takahashi, Prashanthan Sanders, Michel Haïssaguerre, Pierre Jaïs, Li-Fern Hsu, Fréderic Sacher, Jean-Luc Pasquié, Jacques Clementy and Mélèze Hocini |
Abstract: | Aims - Catheter ablation of atrial fibrillation (AF) is centred on pulmonary vein (PV) ablation with or without additional atrial substrate modification. These procedures may be prolonged with significant fluoroscopy exposure. This study evaluates a new non-fluoroscopic navigation system during ablation of AF. Methods and results - Seventy-two patients undergoing catheter ablation of symptomatic drug refractory AF were prospectively randomized to ablation with (n ¼ 35; study group) or without (n ¼ 37; control group) non-fluoroscopic navigation. PV isolation was performed in all patients. In patients with persistent or inducible sustained AF after PV isolation linear ablation was performed by joining the superior PVs. PV isolation was achieved in all patients; fluoroscopy (15.4+3.4 vs. 21.3+6.4 min; P , 0.001) and procedural (52+12 vs. 61+17 min; P ¼ 0.02) durations were significantly reduced in the study group. Linear block was achieved in 37 of the 39 patients; with a significant reduction in fluoroscopy (5.6+2.2 vs. 9.9+4.8 min; P ¼ 0.003) and procedural (14.7+5.5 vs. 26.6+16.9 min; P ¼ 0.007) durations in the study group. After a follow-up of 6.9+2.9 months (range 3–10), 26 (74%) patients in the non-fluoroscopic navigation group and 29 (78%) patients in the control group were arrhythmiafree after the first procedure. Conclusion - This prospectively randomized study demonstrates significant reduction of fluoroscopy exposure and procedural duration using supplementary non-fluoroscopic imaging system for AF ablation. |
Keywords: | Atrial fibrillation Pulmonary vein isolation Linear ablation Non-fluoroscopic imaging |
Rights: | © The European Society of Cardiology 2005. |
DOI: | 10.1093/eurheartj/ehi172 |
Published version: | http://dx.doi.org/10.1093/eurheartj/ehi172 |
Appears in Collections: | Aurora harvest Medicine publications |
Files in This Item:
There are no files associated with this item.