Please use this identifier to cite or link to this item: https://hdl.handle.net/2440/27642
Citations
Scopus Web of Science® Altmetric
?
?
Full metadata record
DC FieldValueLanguage
dc.contributor.authorSale, C.-
dc.contributor.authorYeoh, E.-
dc.contributor.authorScutter, S.-
dc.contributor.authorBezak, E.-
dc.date.issued2005-
dc.identifier.citationActa Oncologica, 2005; 44(4):348-354-
dc.identifier.issn0284-186X-
dc.identifier.issn1651-226X-
dc.identifier.urihttp://hdl.handle.net/2440/27642-
dc.description.abstractThat three dimensional (3D) planning for radiation therapy (RT) of carcinoma of the prostate (CaP) improves radiation dosimetry to the tumour and reduces dose to the rectum and bladder compared with 2D planning, has not been properly evaluated. We addressed this by downloading the CT data files of twenty-two patients who had completed 2D planned RT for CaP onto a 3D planning system and re-planning RT using the same four field technique and dose prescription as the 2D technique. The radiation dose at 100%, 90%, 50% and 0% volumes (D100, D90, D50 and D0) of the Dose Volume Histograms (DVH's) of the GTV, PTV, rectum and bladder, the area under the curves of each DVH and the field sizes were evaluated and compared between the two sets of plans. Repeated measured t-tests were used to compare the means of the different measurements. The D100, D90 and D50 of the GTV, PTV and rectum were increased for the 3D versus the 2D plans (p < 0.05 for each parameter). The area under the rectal DVH was also greater for the 3D plans (p < 0.05). These changes are attributable to the larger field sizes, particularly the length in the 3D compared with the 2D plans.-
dc.description.statementofresponsibilityCharlotte A. Sale, Eric E. K. Yeoh, Sheila Scutter and Eva Bezak-
dc.language.isoen-
dc.publisherTaylor & Francis As-
dc.rights© 2005 Taylor & Francis-
dc.source.urihttp://dx.doi.org/10.1080/02841860510029815-
dc.subjectRectum-
dc.subjectHumans-
dc.subjectProstatic Neoplasms-
dc.subjectNeoplasm Staging-
dc.subjectTreatment Outcome-
dc.subjectRadiotherapy, Conformal-
dc.subjectRadiotherapy Dosage-
dc.subjectRadiotherapy Planning, Computer-Assisted-
dc.subjectArea Under Curve-
dc.subjectDose-Response Relationship, Radiation-
dc.subjectAged-
dc.subjectMale-
dc.subjectUrinary Bladder-
dc.title2D versus 3D radiation therapy for prostate carcinoma: A direct comparison of dose volume parameters-
dc.typeJournal article-
dc.identifier.doi10.1080/02841860510029815-
pubs.publication-statusPublished-
dc.identifier.orcidBezak, E. [0000-0002-1315-1735]-
Appears in Collections:Aurora harvest 2
Chemistry and Physics publications

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.