Title: Assessment of oesophageal motor function using combined perfusion manometry and multi-channel intraluminal impedance measurement in normal subjects
Author: Nguyen, Q.
Tippett, R.
Tippett, M.
Conchillo, J.
Smout, A.
Holloway, R.
Citation: Neurogastroenterology and Motility, 2005; 17(3):458-465
Publisher: Blackwell Publishing Ltd
Issue Date: 2005
ISSN: 1350-1925
1365-2982
Abstract: Multichannel intraluminal impedance (MII) is being used increasingly to assess oesophageal bolus clearance. However, there is no good standardization of the impedance parameters that define 'effective bolus clearance'. The aim of this study was to define these important impedance parameters and to determine their normal values. Concurrent perfusion manometry and MII were performed in 42 healthy volunteers. Ten, 5-mL liquid (saline) boluses and then, 10x5-mL low impedance viscous boluses were tested in each subject in the right-lateral position. Normal values for bolus presence time (BPT) at each site and total bolus transit time (TBTT) were determined from either 'normal' peristaltic responses (amplitude>or=30 mmHg in distal oesophagus) or 'super-normal' peristaltic responses (amplitudes>or=50 mmHg at all sites). The relationship between BPT and TBTT within a response and per-individual performance was determined. A total of 840 swallows of liquids and viscous responses were analysed. BPT and TBTT of viscous swallows were longer than those for liquids. Non-peristaltic responses were significantly more likely not to clear a viscous than a liquid bolus. Within a response, the number of sites with prolonged BPT strongly predicted the incidence of prolonged TBTT. Using impedance criteria, normal oesophageal bolus clearance is defined when an individual completely clears at least 70% of liquid responses and at least 60% of viscous responses. This study provides normal values for impedance measurement of bolus clearance when combined with perfusion manometry. These values will allow standardization of impedance application in oesophageal function testing, in both research and clinical setting.
Keywords: Esophageal Sphincter, Lower
Esophagus
Humans
Manometry
Perfusion
Electric Impedance
Deglutition
Peristalsis
Reference Values
Adolescent
Adult
Aged
Middle Aged
Female
Male
DOI: 10.1111/j.1365-2982.2005.00646.x
Published version: http://dx.doi.org/10.1111/j.1365-2982.2005.00646.x
Appears in Collections:Aurora harvest 2
Medicine publications

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.