Please use this identifier to cite or link to this item: https://hdl.handle.net/2440/132268
Citations
Scopus Web of Science® Altmetric
?
?
Type: Journal article
Title: Fast response hydrogen gas sensor based on Pd/Cr nanogaps fabricated by a single-step bending deformation
Author: Hassan, K.
Tung, T.T.
Yap, P.L.
Nine, M.J.
Kim, H.C.
Losic, D.
Citation: Analytica Chimica Acta, 2020; 1138:49-58
Publisher: Elsevier
Issue Date: 2020
ISSN: 0003-2670
1873-4324
Statement of
Responsibility: 
Kamrul Hassan,Tran Thanh Tung, Pei Lay Yap, Md J.Nine, Hyeon C.Kim, Dusan Losic
Abstract: The development of low-cost and high performing hydrogen gas sensors is important across many sectors, including mining, energy and defense using hydrogen (H2) gas. Herein, we demonstrate a new concept of H2 sensors based on Pd/Cr nanogaps created by using a simple mechanical bending deformation technique. These nanogap sensors can selectively detect the H2 gas based on transduction of the volume expansion after H2 uptake into an electrical signal by palladium-based metal-hydrides that allows closure of nanogaps for electrons flowing or tunneling. While this break-junction architecture, according to literature, can provide several advantages with research gaps in terms of fabricating nanogap sensors with ultra-fast response (≤4 s), the size of nanogap (≤20 nm) and their relationship with time response and recovery as addressed in this paper. Based on the computational modelling outcome, the size of the nanogaps can be investigated in order to optimize the fabrication conditions. Indeed, a single nanogap with optimum width (15 nm) acts as an on-off switch for best performing hydrogen detection. Moreover, with the unique design of Pd/Cr nanogap, the developed sensing device meets major requirement of advanced H2 gas sensor including room temperature (25 °C) operation, detection of trace amounts (10–40,000 ppm), good linearity, ultra-fast response-recovery time (3/4.5 s) and high selectivity. The presented economical lithography-free fabrication method has simple circuitry, low power consumption, recyclability, and favorable aging properties that promises great potential to be used for many practical applications of H2 detection.
Keywords: Gas sensor; hydrogen sensor; nanogap sensor; Pd/Cr nanogap; mechanical deformation
Rights: ©2020 Elsevier B.V. All rights reserved.
DOI: 10.1016/j.aca.2020.09.012
Grant ID: http://purl.org/au-research/grants/arc/IH15000003
Published version: http://dx.doi.org/10.1016/j.aca.2020.09.012
Appears in Collections:ARC Research Hub for Graphene Enabled Industry Transformation publications
Aurora harvest 8
Chemical Engineering publications

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.