Please use this identifier to cite or link to this item: https://hdl.handle.net/2440/87973
Type: Conference paper
Title: Fault identification for nonlinear switched systems: average dwell time approach
Author: Du, D.
Jiang, B.
Shi, P.
Citation: Chinese Control Conference, CCC, 2011, pp.4151-4155
Publisher: IEEE
Publisher Place: USA
Issue Date: 2011
Series/Report no.: Chinese Control Conference
ISBN: 9789881725592
ISSN: 1934-1768
Conference Name: Chinese Control Conference (CCC) (22 Jul 2011 - 24 Jul 2011 : Yantai, China)
Statement of
Responsibility: 
Du Dongsheng, Jiang Bin, and Shi Peng
Abstract: This paper investigates process fault identification for continuous-time nonlinear switched systems. A novel fault estimation algorithm, based on an adaptive fault diagnosis observer and average dwell time technique, is first proposed. In terms of linear matrix inequality, sufficient condition for the existence of the adaptive observer is derived. Simulation results are presented to illustrate the efficiency of the proposed results.
Keywords: Average dwell time; Fault identification; Nonlinear switched systems
Published version: http://ieeexplore.ieee.org/xpl/articleDetails.jsp?arnumber=6000367
Appears in Collections:Aurora harvest 7
Electrical and Electronic Engineering publications

Files in This Item:
There are no files associated with this item.