Please use this identifier to cite or link to this item: https://hdl.handle.net/2440/82600
Citations
Scopus Web of Science® Altmetric
?
?
Type: Journal article
Title: Complications of catheter ablation of atrial fibrillation a systematic review
Author: Aakriti, G.
Perera, T.
Ganesan, A.
Sullivan, T.
Lau, D.
Roberts-Thomson, K.
Brooks, A.
Sanders, P.
Citation: Circulation: Arrhythmia and Electrophysiology, 2013; 6(6):1082-1088
Publisher: Lippincott Williams & Wilkins
Issue Date: 2013
ISSN: 1941-3149
1941-3084
Statement of
Responsibility: 
Aakriti Gupta, Tharani Perera, Anand Ganesan, Thomas Sullivan, Dennis H. Lau, Kurt C. Roberts-Thomson, Anthony G. Brooks, and Prashanthan Sanders
Abstract: BACKGROUND—Atrial fibrillation ablation is an established therapy; however, limited data are available on associated complications. This systematic review determines the incidence and potential predictors of acute complications. METHODS AND RESULTS—Electronic searches were conducted in MEDLINE and EMBASE for English scientific literature up to the 18th June 2012. A total of 2065 references were retrieved and evaluated for relevance. Reference lists of retrieved studies and review articles were examined to ensure all relevant studies were included. Data were extracted from 192 studies, total of 83 236 patients. The incidence of periprocedural complications for catheter ablation of atrial fibrillation was 2.9% (95% confidence interval, 2.6–3.2). There was a significant decrease in the acute complication rate in 2007 to 2012 compared with 2000 to 2006 (2.6% versus 4.0%; P=0.003). The complication rates reported were higher in prospective studies compared with those that retrospectively described complications (3.5% versus 2.7%; P=0.03). There were no significant associations among procedure duration, ablation time or ablation strategy, and acute complication rate. CONCLUSIONS—Catheter ablation of atrial fibrillation has a low incidence of periprocedural complications. The acute complication rate has decreased significantly in recent years. This may reflect improved catheter technology and experience. The use of different strategies across centers worldwide seems to be safe with no established relationship between procedural variables and complication rate.
Keywords: Atrial fibrillation
atrial fibrillation with bradyarrhythmia
catheter ablation
complication, peroperative
review, systematic
Rights: © 2013 American Heart Association, Inc. All rights reserved.
DOI: 10.1161/CIRCEP.113.000768
Grant ID: NHMRC
Published version: http://dx.doi.org/10.1161/circep.113.000768
Appears in Collections:Aurora harvest 4
Medicine publications

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.