Please use this identifier to cite or link to this item: https://hdl.handle.net/2440/53137
Citations
Scopus Web of ScienceĀ® Altmetric
?
?
Type: Journal article
Title: Delayed complications of silicone implants used in orbital fracture repairs
Author: Warrier, S.
Prabhakaran, V.
Davis, G.
Selva-Nayagam, D.
Citation: Orbit: the international journal on orbital disorders, oculoplastic and lacrimal surgery, 2008; 27(3):147-151
Publisher: Taylor & Francis The Netherlands
Issue Date: 2008
ISSN: 0167-6830
1744-5108
Statement of
Responsibility: 
Sunil Warrier, Venkatesh C. Prabhakaran, Garry Davis, Dinesh Selva
Abstract: <h4>Purpose</h4>To report a series of patients who developed late complications secondary to silicone implants used in orbital fracture repairs and review the literature.<h4>Design</h4>Retrospective interventional case series.<h4>Methods</h4>Analysis of records of patients who developed complications following repair of orbital wall fractures with silicone implants.<h4>Results</h4>Over a 5-year period, 4 patients were seen with complications arising from a silicone orbital implant. There were 3 males and 1 female whose ages ranged from 41-73 years. The time interval between initial insertion of implant and development of complications was 1.5, 6, 10, and 20 years. The complications noted were worsening diplopia, recurrent orbital cellulitis, lower lid retraction with restricted upgaze, and orbital abscess. Computed tomographic scans demonstrated the implant in all cases. Histologic examination revealed nonspecific chronic inflammation and fibrosis in all cases and foci of squamous epithelium in one case. Treatment included surgical removal of the implant, resulting in complete resolution or significant improvement in symptoms and signs in all cases.<h4>Conclusion</h4>The use of silicone implants is associated with a wide range of complications, which may occur many years following the original surgery. Surgical removal of the implant usually leads to resolution of symptoms. Given the potential of silicone implants to cause delayed complications, their use in orbital fracture repair is not recommended.
Keywords: Orbital fractures
silicone implants
delayed complications
DOI: 10.1080/01676830802077611
Published version: http://dx.doi.org/10.1080/01676830802077611
Appears in Collections:Aurora harvest
Opthalmology & Visual Sciences publications

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.