Please use this identifier to cite or link to this item: https://hdl.handle.net/2440/43462
Citations
Scopus Web of Science® Altmetric
?
?
Full metadata record
DC FieldValueLanguage
dc.contributor.authorHowie, D.-
dc.contributor.authorWimhurst, J.-
dc.contributor.authorMc Gee, M.-
dc.contributor.authorCarbone, T.-
dc.contributor.authorBadaruddin, B.-
dc.date.issued2007-
dc.identifier.citationJournal of Bone and Joint Surgery: British Volume, 2007; 89B(7):879-886-
dc.identifier.issn0301-620X-
dc.identifier.issn2044-5377-
dc.identifier.urihttp://hdl.handle.net/2440/43462-
dc.descriptionCopyright © 2007 by British Editorial Society of Bone and Joint Surgery-
dc.description.abstractWe investigated 219 revisions of total hip replacement (THR) in 211 patients using a collarless double-taper cemented femoral component. The mean age of the patients was 72 years (30 to 90). The 137 long and 82 standard length stems were analysed separately. The mean follow-up was six years (2 to 18), and no patient was lost to follow-up. Survival of the long stems to re-revision for aseptic loosening at nine years was 98% (95% confidence interval (CI) 94 to 100), and for the standard stems was 93% (95% CI 85 to 100). At five years, one long stem was definitely loose radiologically and one standard stem was probably loose. Pre-operative femoral bone deficiency did not influence the results for the long stems, and corrective femoral osteotomy was avoided, as were significant subsidence, major stress shielding and persistent thigh pain. Because of these reliable results, cemented long collarless double-taper femoral components are recommended for routine revision THR in older patients.-
dc.description.statementofresponsibilityD. W. Howie, J. A. Wimhurst, M. A. McGee, T. A. Carbone and B. S. Badaruddin-
dc.language.isoen-
dc.publisherBritish Editorial Soc Bone Joint Surgery-
dc.source.urihttp://dx.doi.org/10.1302/0301-620x.89b7.18981-
dc.subjectHip Joint-
dc.subjectHumans-
dc.subjectProsthesis Failure-
dc.subjectRadiography-
dc.subjectTreatment Outcome-
dc.subjectArthroplasty, Replacement, Hip-
dc.subjectCementation-
dc.subjectFollow-Up Studies-
dc.subjectProsthesis Design-
dc.subjectHip Prosthesis-
dc.subjectAdult-
dc.subjectAged-
dc.subjectAged, 80 and over-
dc.subjectMiddle Aged-
dc.subjectAustralia-
dc.subjectFemale-
dc.subjectMale-
dc.titleRevision total hip replacement using cemented collarless double-taper femoral components-
dc.typeJournal article-
dc.identifier.doi10.1302/0301-620X.89B7.18981-
pubs.publication-statusPublished-
dc.identifier.orcidHowie, D. [0000-0003-1702-3279]-
dc.identifier.orcidMc Gee, M. [0000-0002-0816-518X]-
dc.identifier.orcidCarbone, T. [0000-0003-4926-7526]-
Appears in Collections:Aurora harvest
Orthopaedics and Trauma publications

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.