Please use this identifier to cite or link to this item: https://hdl.handle.net/2440/42256
Citations
Scopus Web of Science® Altmetric
?
?
Full metadata record
DC FieldValueLanguage
dc.contributor.authorHowie, D.-
dc.contributor.authorNeale, S.-
dc.contributor.authorStamenkov, R.-
dc.contributor.authorMc Gee, M.-
dc.contributor.authorTaylor, D.-
dc.contributor.authorFindlay, D.-
dc.date.issued2007-
dc.identifier.citationJournal of Bone and Joint Surgery: American Volume, 2007; 89A(8):1818-1825-
dc.identifier.issn0021-9355-
dc.identifier.issn1535-1386-
dc.identifier.urihttp://hdl.handle.net/2440/42256-
dc.description© 2007 The Journal of Bone and Joint Surgery, Inc.-
dc.description.abstract<h4>Background</h4>A better understanding of the factors associated with the size and/or progression of osteolytic lesions has been hampered by a lack of sensitivity of radiographic measurement techniques.<h4>Methods</h4>We retrospectively analyzed quantitative computed tomography scans that had been made with use of a high-resolution multi-slice scanner with a metal artifact-suppression protocol. The scans had been made to determine the volume of osteolytic lesions around thirty-five cementless Harris-Galante acetabular components that had been in situ for at least ten years. Repeat scans of thirty hips allowed for the measurement of progression in the size of osteolytic lesions over a one-year period. Associations between the volume of osteolytic lesions, progression in the size of the lesions, polyethylene wear since the time of implantation, change in component position, and patient-related variables (age, gender, body mass index, activity level, walking limitations, joint pain, and function) were determined.<h4>Results</h4>In sixteen of the thirty hips that had repeat computed tomography scans, the lesions progressed in size during the study period. The median size of the lesions in these sixteen hips was 10.3 cm(3) at the time of the initial scan, compared with 13.3 cm(3) at a median of fifteen months later (p = 0.001). Osteolytic lesions measuring >10 cm(3) in volume on the initial scan were 2.5 times (95% confidence interval 1.3 to 4.8 times) more likely to progress in size over one year than smaller lesions were. Patients with greater polyethylene wear rates, higher activity levels, no walking limitations, and larger prosthetic femoral head dimensions (26 or 28 mm) had significantly larger osteolytic lesions (p < 0.0001, p = 0.009, p = 0.006, and p = 0.028, respectively). Progression in the size of the osteolytic lesions over one year was significantly associated with larger initial osteolytic lesions (p = 0.002), greater polyethylene wear rates (p = 0.009), and larger (26 or 28-mm) prosthetic femoral head dimensions (p = 0.019).<h4>Conclusions</h4>There is considerable variation in the rates of progression of the size of osteolytic lesions around stable acetabular components. Lesion size and the progression of lesion size are generally related to polyethylene wear rates, higher patient activity levels, and larger-diameter femoral heads. Osteolytic lesions measuring >10 cm(3) in volume are associated with a high rate of progression.-
dc.description.statementofresponsibilityDonald W. Howie, Susan D. Neale, Roumen Stamenkov, Margaret A. McGee, David J. Taylor, and David M. Findlay-
dc.language.isoen-
dc.publisherJournal Bone Joint Surgery Inc-
dc.source.urihttp://dx.doi.org/10.2106/jbjs.e.01305-
dc.subjectAcetabulum-
dc.subjectHumans-
dc.subjectOsteolysis-
dc.subjectDisease Progression-
dc.subjectProsthesis Failure-
dc.subjectRadiographic Image Interpretation, Computer-Assisted-
dc.subjectTomography, Spiral Computed-
dc.subjectArthroplasty, Replacement, Hip-
dc.subjectChi-Square Distribution-
dc.subjectStatistics, Nonparametric-
dc.subjectRetrospective Studies-
dc.subjectHip Prosthesis-
dc.subjectTime Factors-
dc.subjectAdult-
dc.subjectAged-
dc.subjectMiddle Aged-
dc.subjectFemale-
dc.subjectMale-
dc.titleProgression of acetabular periprosthetic osteolytic lesions measured with computed tomography-
dc.typeJournal article-
dc.identifier.doi10.2106/JBJS.E.01305-
pubs.publication-statusPublished-
dc.identifier.orcidHowie, D. [0000-0003-1702-3279]-
dc.identifier.orcidMc Gee, M. [0000-0002-0816-518X]-
Appears in Collections:Aurora harvest 6
Orthopaedics and Trauma publications

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.