Please use this identifier to cite or link to this item: https://hdl.handle.net/2440/132027
Citations
Scopus Web of Science® Altmetric
?
?
Full metadata record
DC FieldValueLanguage
dc.contributor.authorChapsky, A.-
dc.contributor.authorSpooner, N.A.-
dc.contributor.authorSantos, A.-
dc.contributor.authorRutten, T.-
dc.date.issued2020-
dc.identifier.citationJournal of Physics : Conference Series, 2020, vol.1662, iss.1, pp.012009-1-012009-4-
dc.identifier.issn1742-6588-
dc.identifier.issn1742-6596-
dc.identifier.urihttps://hdl.handle.net/2440/132027-
dc.description.abstractIn radiotherapy practice, 1D and 2D dosimeters are used for dose verification prior to patient treatment. Along with high accuracy and precision of dose measurements that these dosimeters provide, acquisition of dose deposition data in three dimensions requires extrapolation of measured data. Development of a 3D dosimeter would provide continuous information of dose distribution in matter. In this work, NaCl 3D crystal has shown that radiation deposition can be imaged using blue laser stimulation in two dimensions. It was further shown that the intensity of collected signal has near – linear dose dependence, however complete signal readout is required, to compensate for gradual signal collection at different depths along the profile of the stimulating laser beam, due to attenuation of the beam within the crystal. A method to extend dose measurement to three dimensions using imaging is proposed.-
dc.description.statementofresponsibilityA Chapsky, N A Spooner, A Santos and T Rutten-
dc.language.isoen-
dc.publisherIOP Publishing-
dc.relation.ispartofseriesJournal of Physics: Conference Series; 1662-
dc.rightsContent from this work may be used under the terms of the Creative Commons Attribution 3.0 licence. Any further distribution of this work must maintain attribution to the author(s) and the title of the work, journal citation and DOI. Published under licence by IOP Publishing Ltd-
dc.source.urihttps://iopscience.iop.org/issue/1742-6596/1662/1-
dc.title3D dose distribution measurement using 2D imaging from NaCl optical crystals-
dc.typeConference paper-
dc.contributor.conferenceMicro-Mini & Nano Dosimetry and Innovative Technologies in Radiation Oncology (MMND ITRO) (10 Feb 2020 - 16 Feb 2020 : Wollongong, Australia)-
dc.identifier.doi10.1088/1742-6596/1662/1/012009-
dc.publisher.placeonline-
pubs.publication-statusPublished-
dc.identifier.orcidChapsky, A. [0000-0002-8060-292X]-
dc.identifier.orcidSpooner, N.A. [0000-0002-8534-3816]-
dc.identifier.orcidSantos, A. [0000-0001-8482-6982]-
Appears in Collections:IPAS publications

Files in This Item:
File Description SizeFormat 
hdl_132027.pdfPublished version326.33 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.